Scaffolding

Design, erection, scafftag inspection regimes, tube-and-fitting and system scaffolds, mobile towers, loading limits and ties — to ADOSH-SF CoP 26.0, DM Code of Construction Safety Practice, BS EN 12811 and BS 5975.

Scaffold Design and Competence

Scaffolds must be erected, altered and dismantled only under the supervision of a competent scaffold supervisor by trained scaffolders. Any scaffold that is not a basic configuration to a recognised standard configuration guide must be designed and calculated by a competent engineer, with drawings on site. Dubai Municipality and Trakhees require third-party-certified scaffolders and inspectors for major projects.

  • Scaffolder competence

    Recognised scaffolding certification (e.g. CISRS or equivalent third-party card)

    critical
  • Scaffold supervisor

    Named, competent, present during erection, alteration and dismantling

    critical
  • Design required when

    Height >8 m free-standing, non-standard configuration, loading >2 kN/m², cantilever, birdcage over voids, sheeted/netted scaffolds

    critical
  • Design documents on site

    Stamped drawings and calculations available for inspection

    critical
  • Standard configuration reference

    BS EN 12811-1 / BS 5975 / TG20-style compliance sheet

    standard

Dimensional and Component Requirements

ElementRequirementReference
Main guardrail height950–1,150 mm above the platformBS EN 12811-1 / ADOSH-SF CoP 26.0
Maximum bay length2.4 m (tube-and-fitting) / 2.5 m (system scaffold)ADOSH-SF CoP 26.0
Maximum lift height2.0 m between platform levelsADOSH-SF CoP 26.0
Intermediate guardrailMax unprotected gap 470 mmBS EN 12811-1
Toe boardMinimum 150 mm high, fitted to all open edgesBS EN 12811-1 / DM Code
Platform width — general accessMinimum 600 mm clear (3 boards)ADOSH-SF CoP 26.0 / BS EN 12811-1
Platform width — with materialsMinimum 900 mm clear (4–5 boards)BS EN 12811-1
Gap between platform and structureMaximum 300 mm, otherwise infill or edge protectionADOSH-SF CoP 26.0
Board overhang at supportsMinimum 50 mm, maximum 4x board thicknessBS 5975
Base plates / sole boardsMandatory on all standards; sole boards on sand or soft groundBS EN 12811-1
Tie spacingPer design; typically every 4 m vertically and horizontally on sheeted scaffoldsBS 5975
Ladder access riseLanding/rest platform at maximum 9 m vertical intervalsADOSH-SF CoP 26.0

Sheeting or debris netting dramatically increases wind load. A scaffold designed unsheeted must never be sheeted without a re-design and additional ties — this is one of the most common collapse causes in the region.

Load Classes

  • Load class displayed

    Stated on the scafftag and design sheet

    critical
  • Loaded bays

    Only bays designed for material storage may be loaded

    critical
  • Simultaneous loaded lifts

    Per design — commonly one loaded lift per bay

    standard
ClassUniform loadTypical use
10.75 kN/m²Inspection and very light access only
21.50 kN/m²Light duty — painting, cleaning, rendering touch-up
32.00 kN/m²General duty — most construction trades
43.00 kN/m²Heavy duty — masonry, blockwork
54.50 kN/m²Very heavy — stone/heavy cladding storage
66.00 kN/m²Special design — engineer calculation mandatory

Scafftag Inspection Regime

Every scaffold must carry a tag at each access point showing its status. A scaffold under erection, alteration or dismantle carries a red 'Do Not Use' tag with the tie/board status; only when a competent inspector has signed it off does it carry a green tag.

  • Inspection before first use

    By a competent inspector, recorded and tagged

    critical
  • Routine inspection interval

    Every 7 days maximum — ADOSH-SF CoP 26.0

    critical
  • Handover certificate

    Scaffold handover certificate issued and signed by the competent scaffold inspector before first use — ADOSH-SF CoP 26.0

    critical
  • Additional inspections

    After alteration, impact, high wind, sandstorm or rain event

    critical
  • Record retention

    Inspection register kept on site for the project duration

    standard
  • Tag content

    Scaffold ID, load class, inspector name, date, next inspection due

    critical
  • Incomplete scaffold

    Red tag and physical access blocked at every ladder/stair

    critical

Mobile Access Towers

Mobile aluminium towers must be assembled strictly to the manufacturer's instruction manual using an advance-guardrail or through-the-trap method, so the erector is never exposed to an unguarded edge.

  • Assembly method

    Advance guardrail (AGR) or 3T through-the-trap only

    critical
  • Height-to-base ratio — indoor

    Maximum 3.5:1

    critical
  • Height-to-base ratio — outdoor

    Maximum 3:1

    critical
  • Stabilisers / outriggers

    Fitted per the manual before the tower is climbed

    critical
  • Castors

    Locked while in use; never move the tower with a person or materials on it

    critical
  • Access

    Internal ladder only — never climb the outside frame

    critical
  • Manual on site

    Manufacturer instruction manual available at the tower

    standard