Working at Height

Edge Protection & Working at Height

Edge protection for villa and townhouse works, shuttering/de-shuttering, blockwork scaffolding, and glass curtain wall installation.

7 min
Video
10
Quiz questions
8 / 10
Pass threshold
0%
Your progress

Learning Objectives

  • Specify compliant edge protection: top rail, mid rail, toe board.
  • Protect openings and drops during shuttering and de-shuttering.
  • Set up blockwork scaffolding to Trakhees CSR standards.
  • Manage the fall risk during glass curtain wall installation.
  • Inspect edge protection weekly and record.

Training Video

Pro

Preview

7-minute video

Unlock this training video

The first 3 modules are free. Upgrade to Pro to watch every module, save progress, and issue certificates.

Upgrade to Pro

Module Content

1. Compliant Edge Protection

Top rail at 950–1150 mm, mid rail no gap > 470 mm, toe board minimum 150 mm high. Must withstand a 1 kN horizontal force. Timber acceptable if graded, steel preferred.

2. Openings

Every floor opening, stair void and riser is covered with a load-rated cover marked 'DO NOT REMOVE' and secured, or protected with fixed barriers. Removal only under PTW.

3. Shuttering & De-shuttering

During shutter erection and strike, edge protection may need temporary removal — a Working at Height PTW with harness anchor points is required. Never work below a shutter being struck.

4. Blockwork Scaffolding

Independent scaffolds with double guardrails, toe boards, sole boards on adequate bearing. Tagged Green by a competent scaffold inspector before use.

5. Glass Curtain Wall

External work with MEWPs or scaffold, fall arrest above 1.8 m, no lone working, weather monitoring for wind. Glass loading follows the manufacturer's rigging plan.

6. Inspection Regime

Edge protection inspected weekly and after any disturbance. Recorded in the scaffold/edge protection register. Any deficiency = red tag + immediate correction.

Knowledge Assessment

1. Compliant edge protection has top rail at what height?

2. Toe boards must be at least how high?

3. Floor opening covers must be:

4. During de-shuttering, if edge protection must be removed:

5. Blockwork scaffolds must be tagged by:

6. Glass curtain wall external work above 1.8 m requires:

7. Edge protection must be inspected:

8. The mid rail gap must not exceed:

9. Edge protection must withstand a horizontal force of at least:

10. A deficiency found during edge protection inspection results in:

Certificate

Pass the quiz (8 / 10) to unlock your certificate.

Acknowledgement

By signing below, you confirm you have watched the training video, understood the material, and will apply these controls on site.

Complete the video and pass the quiz (8 / 10) to unlock signing.