Checkpoints
87
Open live checklist
#AreaCheckpoint / RequirementEvidence / Acceptance CriteriaResponsibleFrequency
1Site DistributionExtinguisher density per floor/zone meets minimum count for floor area under Civil Defence codeFloor plan headcount of units matches minimum ratio calculationHSE OfficerQuarterly
2Site DistributionSite office, labour camp mess and stores each have dedicated extinguisher coverageCoverage checklist per facility with unit serial numbersHSE OfficerMonthly
3Site DistributionExtinguishers provided at each hoist/elevator lobby and stair landing at heightFloor-by-floor inspection log confirming presenceSite SupervisorMonthly
4Site DistributionTemporary works compound (batching plant, workshop, generator yard) has extinguisher coverage matching hazard classCompound risk assessment matched to installed unitsHSE OfficerMonthly
5Vehicle & Plant Mounted UnitsSite vehicles and mobile plant fitted with in-cab extinguisher of correct classVehicle checklist confirms presence and mounting securityPlant OperatorWeekly
6Vehicle & Plant Mounted UnitsGenerator and fuel storage area extinguishers rated for Class B fire riskExtinguisher label class matches fuel storage hazard ratingHSE OfficerMonthly
7Vehicle & Plant Mounted UnitsWelding/cutting rigs carry dedicated portable extinguisher during operationRig inspection checklist confirms unit attached before work startsHot Work SupervisorPer use
8Cylinder IdentificationEach extinguisher bears unique barcode/QR asset tag linked to digital maintenance recordQR scan retrieves matching maintenance history on inspection appHSE OfficerMonthly
9Cylinder IdentificationColour-coding on cylinder body correct for extinguishing agent type per codeColour band checked against UAE Fire Code colour reference chartHSE OfficerQuarterly
10Cylinder IdentificationManufacture/charge date stamped legibly on cylinder base or collarDate stamp readable and recorded on registerHSE OfficerMonthly
11Storage ConditionsExtinguishers not exposed to direct sunlight, extreme heat sources or corrosive atmosphereLocation shading/ventilation assessment during walk-roundHSE OfficerMonthly
12Storage ConditionsAmbient temperature at storage location within manufacturer operating rangeThermometer reading logged for outdoor-mounted unitsHSE OfficerMonthly
13Storage ConditionsExtinguisher bracket fixing to wall/structure is secure and rated for cylinder weightBracket pull-test or visual fixing check completedSite SupervisorQuarterly
14Chemical/Flammable Store CoverageChemical/paint store equipped with foam or dry powder extinguisher matching MSDS fire classMSDS fire-fighting section cross-checked with installed unit typeHSE OfficerMonthly
15Chemical/Flammable Store CoverageLPG/gas cylinder storage area has extinguisher positioned outside blast radius per codeStorage layout plan shows extinguisher setback distanceHSE OfficerQuarterly
16Kitchen/Pantry CoverageSite canteen/kitchen fitted with wet chemical (Class F) extinguisher near cooking equipmentUnit class label confirms wet chemical type at kitchen pointHSE OfficerMonthly
17Kitchen/Pantry CoverageKitchen exhaust hood/duct area has extinguisher access without crossing hot surfacesLayout inspection confirms safe access pathSite SupervisorMonthly
18Electrical Room CoverageSubstation/MCC room fitted with CO2 extinguisher rated for energized electrical equipmentUnit class label confirms CO2/dielectric ratingHSE OfficerMonthly
19Electrical Room CoverageExtinguisher positioned outside arc-flash boundary but within reachable travel distanceElectrical safety study cross-checked with extinguisher locationElectrical EngineerQuarterly
20Post-Incident ActionsFire incident report completed within 24 hours identifying extinguisher used and effectivenessIncident report form with extinguisher serial number referenceHSE ManagerAs required
21Post-Incident ActionsLessons-learned review conducted after any fire event affecting extinguisher deploymentReview minutes with corrective actions assignedHSE ManagerAs required
22Post-Incident ActionsDischarged extinguisher tagged 'out of service' immediately pending rechargeOut-of-service tag applied and logged same dayHSE OfficerImmediate
23Handover to SubcontractorsSubcontractor work areas verified to have adequate extinguisher provision before mobilizationMobilization checklist includes fire equipment sign-offHSE OfficerBefore mobilization
24Handover to SubcontractorsSubcontractor fire watch personnel briefed on nearest extinguisher locationsBriefing record signed by fire watch personnelHot Work SupervisorPer shift
25Signage & MarkingFloor marking/hatching identifies extinguisher stand location to prevent obstructionFloor paint marking visible and undamagedSite SupervisorMonthly
26Signage & MarkingDirectional 'fire point' signage installed at corridor junctions leading to extinguisherSignage placement matches fire safety plan layoutHSE OfficerQuarterly
27Signage & MarkingBilingual (Arabic/English) instructional pictogram displayed at each fire pointPictogram condition and legibility checkedHSE OfficerMonthly
28Weather ProtectionOutdoor-mounted extinguishers fitted with weatherproof cabinet where exposed to rain/dustCabinet integrity and drainage checked during inspectionSite SupervisorMonthly
29Weather ProtectionCabinet door hinges and latch operate freely without corrosion in humid/coastal conditionsFunction check of cabinet hardwareSite SupervisorMonthly
30Basement & Confined AreasBasement car park/plant room extinguisher provision meets enhanced density requirementBasement layout plan verified against code minimum spacingHSE OfficerQuarterly
31Basement & Confined AreasConfined space entry points have extinguisher staged at access point during hot workConfined space permit cross-referenced with extinguisher stagingConfined Space SupervisorPer permit
32Extinguisher Removal ControlRemoval of extinguisher from designated location for any reason logged and replacement arranged same dayRemoval/replacement log entry with reason and timestampHSE OfficerAs required
33Extinguisher Removal ControlTemporary relocation of extinguisher during works communicated to site personnel via noticeRelocation notice posted at original and new locationSite SupervisorAs required
34Fire Point Layout VerificationFire point layout as-built matches submitted Civil Defence approved fire safety drawingAs-built markup compared against approved drawing setHSE ManagerQuarterly
35Fire Point Layout VerificationChanges to site layout (new structures/hoardings) trigger re-assessment of extinguisher coverageLayout change log with re-assessment sign-offHSE ManagerUpon layout change
36Multi-Storey ProgressionExtinguisher provision extended progressively to each newly completed floor/levelFloor handover checklist includes fire equipment installation confirmationSite EngineerPer floor completion
37Multi-Storey ProgressionTemporary works/scaffolding towers above 3 levels equipped with extinguisher at working platformScaffold inspection tag cross-references extinguisher presenceScaffold SupervisorWeekly
38Contractual ComplianceFire fighting equipment provision complies with project fire strategy report requirementsFire strategy report clause matched against site provisionHSE ManagerQuarterly
39Contractual ComplianceClient/consultant fire safety audit findings for extinguishers closed within agreed timeframeAudit tracker with closure evidence and datesHSE ManagerPer audit
40Waste & Housekeeping AreasWaste skip/segregation area has extinguisher provision addressing combustible waste riskArea risk assessment matched to installed extinguisher classHSE OfficerMonthly
41Waste & Housekeeping AreasExtinguisher access to waste storage area not blocked by accumulated skips or palletsAccess clearance verified during housekeeping inspectionSite SupervisorWeekly
42Night Shift ProvisionExtinguisher locations illuminated adequately for night shift visibility and accessLux level check at fire point during night inspectionHSE OfficerMonthly
43Night Shift ProvisionNight shift supervisor briefed on fire point locations and equipment status at shift handoverShift handover log includes fire equipment statusNight Shift SupervisorDaily
44Inspection App/Digital RecordsMobile inspection app data synced and backed up to central HSE databaseSync log confirms successful upload with timestampHSE OfficerWeekly
45Inspection App/Digital RecordsDigital inspection photos retained and linked to extinguisher serial number for audit trailPhoto repository cross-referenced with asset registerHSE OfficerMonthly
46Spare Parts & ConsumablesSpare seals, pins and tags stocked for immediate re-sealing after inspectionStore inventory shows adequate spare stock levelStore KeeperMonthly
47Spare Parts & ConsumablesReplacement brackets and signage available for damaged fire point fittingsStore inventory record for bracket/signage stockStore KeeperMonthly
48Contractor HandbackExtinguisher inventory reconciled and handed over to facilities management at project completionHandover certificate listing all units, locations and service datesHSE ManagerProject close-out
49Contractor HandbackAs-maintained fire equipment register transferred to building owner/FM team with full service historyRegister transfer receipt signed by receiving partyHSE ManagerProject close-out
50Random Spot ChecksUnannounced spot check of extinguisher condition and accessibility performed by senior managementSpot check report with findings and corrective actionsProject DirectorQuarterly
51Registration & ApprovalExtinguisher model/type is Civil Defence approved and listed on the approved products registerApproval certificate/label matches installed unit model numberHSE OfficerOn installation
52Registration & ApprovalSite fire fighting equipment schedule is registered with local Civil Defence and matches installed count/typeCivil Defence approved fire safety plan/schedule cross-checked against site inventoryHSE ManagerQuarterly
53Registration & ApprovalThird-party maintenance contractor holds valid Civil Defence approval for servicing/refillingContractor Civil Defence license copy on fileHSE ManagerAnnually
54Placement & AccessExtinguisher mounted on bracket/stand at correct height (handle 1.0-1.5 m from floor)Visual measurement against UAE Fire & Life Safety Code clearance requirementSite SupervisorMonthly
55Placement & AccessTravel distance to nearest extinguisher does not exceed code limit for occupancy/hazard classFire safety plan travel-distance markup verified on site walkHSE OfficerMonthly
56Placement & AccessExtinguisher location unobstructed by materials, stacked goods, vehicles or scaffolding1m clear access zone maintained; photo evidence in walk-round logSite SupervisorWeekly
57Placement & AccessLocation signage/photoluminescent identification sign installed above unitSign visible from approach direction, not obscuredSite SupervisorMonthly
58Placement & AccessExtinguisher type matches fire risk class of area (CO2 near electrical panels, dry powder for general, foam for flammable liquids)Area fire risk assessment matched to extinguisher class on inspection tagHSE OfficerQuarterly
59Physical ConditionCylinder body free of corrosion, dents, leakage or physical damageVisual inspection recorded on tag with inspector initialsHSE OfficerMonthly
60Physical ConditionPressure gauge needle in green operable bandGauge reading recorded on inspection tagHSE OfficerMonthly
61Physical ConditionSafety pin and tamper seal intact and unbrokenSeal number logged and compared to previous inspectionHSE OfficerMonthly
62Physical ConditionDischarge hose/nozzle free of cracks, blockage or perishingHose flexed and visually checked, no cracking observedHSE OfficerMonthly
63Physical ConditionOperating instructions label legible in English and ArabicLabel wording readable at arm's lengthHSE OfficerMonthly
64Physical ConditionExtinguisher weight checked against nameplate weight (for CO2/dry powder) to confirm chargeWeighing scale reading within manufacturer toleranceMaintenance ContractorAnnually
65Testing & ServicingAnnual maintenance/service carried out by approved third party contractorService certificate and updated tag date affixed to cylinderMaintenance ContractorAnnually
66Testing & ServicingHydrostatic pressure test conducted per cylinder manufacture date cycle (5-yearly typical)Hydrostatic test certificate with stamped date on cylinderMaintenance Contractor5-yearly
67Testing & ServicingRefilled/recharged units re-commissioned with new service tag and sealRecharge record matching extinguisher serial numberMaintenance ContractorAs required
68Testing & ServicingExpired or condemned units removed from site immediately and replacedReplacement log with old unit disposal recordHSE OfficerImmediate on failure
69DocumentationIndividual extinguisher inspection tag/card updated at each inspection with signature and dateTag entries continuous with no gapsHSE OfficerMonthly
70DocumentationMaster fire equipment register maintained showing serial number, location, type, last/next service dateRegister cross-checked against physical countHSE ManagerMonthly
71DocumentationNon-conformances raised for missing/defective units tracked to closureNCR log with closure evidence and photosHSE ManagerAs raised
72Fire Hose Reel & CabinetFire hose reel valve operates smoothly and hose unrolls without kinksFunction test recorded during inspectionHSE OfficerMonthly
73Fire Hose Reel & CabinetHose reel cabinet glass/door intact, break-glass point unobstructedVisual check of cabinet integritySite SupervisorMonthly
74Fire Hose Reel & CabinetHose reel water supply pressure within design range at nozzlePressure gauge reading logged during flow testMaintenance ContractorQuarterly
75Fire Hose Reel & CabinetHose reel cabinet clearly signed and unlocked/accessible in emergencyCabinet door opens without key or toolHSE OfficerMonthly
76Fire BlanketFire blanket present in designated hot-work/kitchen areas within quick-release pouchPouch pull-tab intact and unobstructedSite SupervisorMonthly
77Fire BlanketFire blanket fabric free of holes, contamination or prior deployment without replacementVisual inspection of blanket condition through pouch windowHSE OfficerMonthly
78Fire Extinguisher Trolley/Mobile UnitsWheeled/trolley-mounted extinguishers (for hot works/welding) secured and mobile without obstructionWheels/castors free-rolling, unit upright and stableHSE OfficerWeekly
79Fire Extinguisher Trolley/Mobile UnitsMobile unit accompanies hot work permit activity at point of workHot work permit cross-referenced with extinguisher deployment logHot Work SupervisorPer permit
80Training & CompetencySite personnel trained in extinguisher selection and basic operation (PASS technique)Training attendance record and competency assessmentHSE ManagerAnnually
81Training & CompetencyFire warden/marshal list current and each warden aware of assigned extinguisher zoneFire warden appointment list posted and matches induction recordsHSE ManagerQuarterly
82Training & CompetencyToolbox talk conducted covering fire extinguisher use after any incident or near-missToolbox talk register with topic and attendee signaturesSite SupervisorAs required
83Emergency ReadinessFire extinguisher deployed during drill/incident is replaced or refilled before next shiftReplacement/refill record dated within 24 hours of useHSE OfficerAs required
84Emergency ReadinessFire assembly point map indicates extinguisher/hose reel locations relative to escape routesFire safety plan displayed at site entrance and officeHSE ManagerQuarterly
85Emergency ReadinessSpare/reserve extinguishers stocked in store for rapid replacement of condemned unitsStore inventory record showing spare stock countStore KeeperMonthly
86External AuditCivil Defence periodic site inspection findings closed out within stipulated timeframeCivil Defence inspection report and closure evidence filedHSE ManagerPer visit
87External AuditInsurance/third-party fire risk audit recommendations tracked to completionAudit action tracker with status and target datesHSE ManagerAnnually

Each checkpoint records Status (Yes / No / N/A), Comments, Corrective Action and Sign-off. Switch to Complete in-app to fill it here, or download the blank version to complete on site.

Next step

Turn this into evidence you can hand over

Replace scattered spreadsheets and WhatsApp threads with one HSE operations system built around UAE authority expectations.

  • Built around UAE authoritiesADOSH-SF, Trakhees, DM, DCD, MOIAT and ISO 45001 structures.
  • Usable the same dayTemplates and registers are pre-filled with your company details.
  • Evidence, not just formsEvery record carries dates, signatures and an export you can hand over.