89
| # | Area | Checkpoint / Requirement | Evidence / Acceptance Criteria | Responsible | Frequency |
|---|---|---|---|---|---|
| 1 | First Aid & Medical Readiness | AED (automated external defibrillator) provided in office where headcount exceeds project threshold | AED inspection log with battery/pad expiry checked | HSE Officer | Monthly |
| 2 | IT & Data Safety | Server/comms room fitted with independent cooling and clean-agent fire suppression | Suppression system service certificate current | IT Coordinator | Quarterly |
| 3 | Ergonomics & Occupational Health | Anti-fatigue matting provided at reception/standing workstations | Visual inspection confirms matting present and in good condition | Facilities Supervisor | Quarterly |
| 4 | Waste & Environmental Management | Single-use plastics minimised in pantry area with reusable alternatives provided | Pantry inspection record confirming reusable items in use | HSE Officer | Quarterly |
| 5 | Office Location & Setup | Site office positioned outside crane radius, lifting zones and vehicle swing paths | Site layout plan shows office location clear of hazard zones with marked safe distance | HSE Officer | Prior to installation |
| 6 | Office Location & Setup | Office set on stable, level, compacted ground or approved foundation | Ground bearing/foundation inspection record signed off | Site Engineer | Prior to installation |
| 7 | Office Location & Setup | Portacabin/office units anchored against wind uplift as per manufacturer spec | Anchoring/tie-down inspection checklist with photos | HSE Officer | Monthly |
| 8 | Office Location & Setup | Access steps/ramps to office fitted with handrails and anti-slip treads | Visual inspection log, handrail height ≥900mm verified | HSE Officer | Monthly |
| 9 | Office Location & Setup | Office located with min 2 unobstructed access/egress routes | Site walk-down confirms two clear routes, no stored material blocking | HSE Officer | Weekly |
| 10 | Office Location & Setup | External steps and walkways free of trip hazards, debris and standing water | Weekly housekeeping inspection record | Site Supervisor | Weekly |
| 11 | Office Location & Setup | Office signage displaying building number/name and emergency assembly point direction | Photo evidence of signage installed and legible | HSE Officer | Monthly |
| 12 | Office Location & Setup | Adequate lighting provided at external entrances for night visibility | Lux level check or visual confirmation during night shift | HSE Officer | Monthly |
| 13 | Fire Safety & Emergency Preparedness | Portable fire extinguishers (CO2/DCP) provided at correct type/rating for office use | Extinguisher inspection tags current, correct class matched to risk | HSE Officer | Monthly |
| 14 | Fire Safety & Emergency Preparedness | Fire extinguishers mounted on brackets at accessible height, unobstructed | Visual check confirms mounting height 1.0-1.5m and clear 1m radius | HSE Officer | Monthly |
| 15 | Fire Safety & Emergency Preparedness | Fire extinguishers serviced/pressure-tested annually by certified vendor | Valid service certificate and tag date within 12 months | HSE Officer | Annually |
| 16 | Fire Safety & Emergency Preparedness | Smoke detectors installed and functional in each office cabin/room | Test log confirming audible alarm on activation | HSE Officer | Monthly |
| 17 | Fire Safety & Emergency Preparedness | Emergency evacuation plan displayed at office entrance and common areas | Evacuation plan poster present, matches current layout | HSE Officer | Monthly |
| 18 | Fire Safety & Emergency Preparedness | Assembly point clearly marked, sized for occupancy and free from obstruction | Site inspection confirms marking and unobstructed access | HSE Officer | Monthly |
| 19 | Fire Safety & Emergency Preparedness | Fire evacuation drill conducted for office occupants | Drill record with headcount, timing and lessons learned | HSE Manager | Quarterly |
| 20 | Fire Safety & Emergency Preparedness | Emergency contact numbers (Civil Defence, ambulance, site control room) posted near phones/notice boards | Photo of posted numbers, verified current | HSE Officer | Quarterly |
| 21 | Fire Safety & Emergency Preparedness | No accumulation of combustible materials (paper, cardboard) near electrical panels or exits | Housekeeping inspection with photographic evidence | Site Supervisor | Weekly |
| 22 | Fire Safety & Emergency Preparedness | Fire exit doors open outward, unlocked during occupied hours and unobstructed | Daily walk-through confirms exits clear and operable | HSE Officer | Daily |
| 23 | Electrical Safety | Office distribution boards fitted with ELCB/RCD protection | DB inspection tag and test record showing trip test pass | Electrical Supervisor | Monthly |
| 24 | Electrical Safety | All electrical cables routed overhead or protected, not trailing on floor | Visual inspection confirms no trailing/damaged cables | HSE Officer | Weekly |
| 25 | Electrical Safety | Sockets and switches free from cracks, exposed wiring or overloading | Visual inspection checklist per office unit | HSE Officer | Monthly |
| 26 | Electrical Safety | Portable Appliance Testing (PAT) carried out on office equipment | PAT test labels current, register updated | Electrical Supervisor | Quarterly |
| 27 | Electrical Safety | AC units and electrical fittings earthed and bonded correctly | Earth continuity test record within acceptable resistance | Electrical Supervisor | Quarterly |
| 28 | Electrical Safety | No use of unauthorized multi-plug adaptors or daisy-chained extension leads | Inspection confirms only approved extension reels in use | HSE Officer | Weekly |
| 29 | Electrical Safety | Main isolator/emergency electrical shut-off clearly labelled and accessible | Photo evidence of labelled isolator with clear access | Electrical Supervisor | Monthly |
| 30 | Electrical Safety | Electrical panel rooms/cabinets kept locked with warning signage | Inspection confirms lock in place and signage visible | HSE Officer | Monthly |
| 31 | Electrical Safety | Licensed electrician certification verified for all office electrical works | Valid trade license/certificate on file | HSE Officer | Prior to work |
| 32 | Electrical Safety | Emergency lighting operational for power outage during occupied hours | Function test log with battery backup duration recorded | Electrical Supervisor | Monthly |
| 33 | Housekeeping & General Office Conditions | Office floors kept clean, dry and free of trip hazards | Daily housekeeping checklist signed by cleaner/supervisor | Site Supervisor | Daily |
| 34 | Housekeeping & General Office Conditions | Waste bins provided, emptied regularly and segregated (general/recyclable) | Waste collection log and bin condition check | Site Supervisor | Daily |
| 35 | Housekeeping & General Office Conditions | Furniture (desks, chairs, cabinets) in good condition, no sharp edges or instability | Furniture condition inspection checklist | Site Supervisor | Monthly |
| 36 | Housekeeping & General Office Conditions | Filing cabinets and shelving secured/anchored to prevent tipping | Visual inspection confirms anchoring straps/brackets fitted | HSE Officer | Quarterly |
| 37 | Housekeeping & General Office Conditions | Windows and doors functional, glazing intact with no cracks | Visual inspection record, defects logged for repair | Site Supervisor | Monthly |
| 38 | Housekeeping & General Office Conditions | Pest control programme implemented for office area | Pest control service report from licensed contractor | HSE Officer | Quarterly |
| 39 | Housekeeping & General Office Conditions | Office ventilation/air conditioning maintained and filters cleaned | AC maintenance service record with filter cleaning date | Facilities Supervisor | Monthly |
| 40 | Housekeeping & General Office Conditions | Noise levels inside office kept within comfortable working limits | Periodic noise level spot-check record | HSE Officer | Quarterly |
| 41 | First Aid & Medical Readiness | First aid box provided in office, stocked per UAE OSHAD requirements | First aid box inventory checklist with contents verified | HSE Officer | Monthly |
| 42 | First Aid & Medical Readiness | First aid box contents within expiry date | Expiry date check log, expired items replaced | HSE Officer | Monthly |
| 43 | First Aid & Medical Readiness | Trained first aider identified for office area with certificate on display | Valid first aid certificate and nomination notice posted | HSE Manager | Annually |
| 44 | First Aid & Medical Readiness | First aid box location signposted and known to all office occupants | Toolbox talk attendance record confirming awareness | HSE Officer | Quarterly |
| 45 | First Aid & Medical Readiness | Accident/incident reporting register maintained and accessible in office | Register reviewed, entries up to date | HSE Officer | Monthly |
| 46 | First Aid & Medical Readiness | Eyewash station provided if hazardous chemicals stored/used in office(printer toner etc.) | Eyewash station inspection tag and flow test record | HSE Officer | Monthly |
| 47 | First Aid & Medical Readiness | Emergency evacuation chair/procedure available for occupants with mobility needs | Equipment inspection record or documented arrangement | HSE Officer | Quarterly |
| 48 | First Aid & Medical Readiness | Nearest hospital/clinic route map displayed in office | Map posted with route and contact number verified | HSE Officer | Quarterly |
| 49 | Document Control & HSE Compliance Records | Valid civil defence approval/NOC available for office cabins | Copy of NOC certificate filed and current | HSE Manager | Annually |
| 50 | Document Control & HSE Compliance Records | Site HSE plan and method statements accessible in office for reference | Document register confirms current revisions available | HSE Officer | Quarterly |
| 51 | Document Control & HSE Compliance Records | Statutory notices (labour law, HSE policy, insurance) displayed in office | Photo evidence of notices displayed and legible | HSE Officer | Quarterly |
| 52 | Document Control & HSE Compliance Records | Visitor sign-in register maintained at office reception | Register reviewed for completeness and legibility | Site Administrator | Daily |
| 53 | Document Control & HSE Compliance Records | Emergency contact list updated with current site personnel names/numbers | List cross-checked against current staffing, dated | HSE Officer | Monthly |
| 54 | Document Control & HSE Compliance Records | Office equipment calibration certificates (if applicable, e.g. gas detectors stored) filed | Calibration certificate register checked for validity | HSE Officer | Quarterly |
| 55 | Document Control & HSE Compliance Records | Environmental permits/waste manifests filed and accessible in office | Document audit confirms filing system complete | HSE Officer | Quarterly |
| 56 | Document Control & HSE Compliance Records | HSE inspection and audit reports archived in office document control system | Document control log shows retrieval within 24 hours on request | HSE Officer | Quarterly |
| 57 | Ergonomics & Occupational Health | Office chairs adjustable and suitable for prolonged desk work | Ergonomic assessment checklist completed per workstation | HSE Officer | Annually |
| 58 | Ergonomics & Occupational Health | Computer workstations arranged to avoid glare and awkward posture | Workstation assessment record with corrective actions closed | HSE Officer | Annually |
| 59 | Ergonomics & Occupational Health | Adequate desk space and legroom provided per occupant | Space audit against occupancy plan | Facilities Supervisor | Annually |
| 60 | Ergonomics & Occupational Health | Drinking water supply available and tested for potability | Water quality test certificate current | HSE Officer | Quarterly |
| 61 | Ergonomics & Occupational Health | Air quality (CO2/humidity/temperature) within acceptable comfort range | Indoor air quality spot-check record | HSE Officer | Quarterly |
| 62 | Ergonomics & Occupational Health | Rest breaks and heat stress management applied for office staff during summer | Heat stress policy communicated, records of compliance | HSE Officer | Seasonal (Jun-Sep) |
| 63 | Ergonomics & Occupational Health | Manual handling of files/equipment in office assessed for ergonomic risk | Manual handling risk assessment on file | HSE Officer | Annually |
| 64 | Ergonomics & Occupational Health | Occupational health records for office staff maintained confidentially | Medical record register access-controlled, storage verified | HSE Officer | Annually |
| 65 | Security & Access Control | Office entry restricted to authorized personnel and registered visitors | Access control log/security gate record reviewed | Security Supervisor | Daily |
| 66 | Security & Access Control | CCTV coverage provided for office entrance and reception if required by project | CCTV functionality check log | Security Supervisor | Monthly |
| 67 | Security & Access Control | Keys/access cards for office issued and tracked via register | Key/access card issue register up to date | Site Administrator | Monthly |
| 68 | Security & Access Control | Confidential documents secured in lockable cabinets | Spot check confirms cabinets locked when unattended | HSE Officer | Weekly |
| 69 | Security & Access Control | Security guard briefed on office emergency procedures and evacuation duties | Briefing attendance record signed | Security Supervisor | Quarterly |
| 70 | Security & Access Control | Lost/found property procedure established for office area | Procedure documented and communicated to staff | Site Administrator | Annually |
| 71 | Security & Access Control | Out-of-hours office access logged and authorized | Access log reviewed for anomalies | Security Supervisor | Monthly |
| 72 | Signage & Communication | Mandatory PPE signage displayed at office entrance if adjoining site areas | Signage inspection confirms visibility and condition | HSE Officer | Monthly |
| 73 | Signage & Communication | No smoking signage displayed throughout office premises | Visual inspection confirms signage present at all entry points | HSE Officer | Monthly |
| 74 | Signage & Communication | HSE notice board updated with current campaigns, statistics and alerts | Notice board content dated within last update cycle | HSE Officer | Weekly |
| 75 | Signage & Communication | Muster point map and floor evacuation routes displayed on each floor/cabin | Map verified against current layout, posted at eye level | HSE Officer | Quarterly |
| 76 | Signage & Communication | Toolbox talk topics and schedule posted for office-based staff awareness | Posted schedule matches actual toolbox talk records | HSE Officer | Weekly |
| 77 | Signage & Communication | Language-appropriate signage provided for multinational workforce understanding | Signage review confirms pictorial/multi-language format used | HSE Officer | Annually |
| 78 | Fire Safety & Emergency Preparedness (Additional) | Fire blanket provided in pantry/kitchenette area of office | Fire blanket present, inspection tag current | HSE Officer | Monthly |
| 79 | Fire Safety & Emergency Preparedness (Additional) | Emergency evacuation warden appointed for office building with visible ID | Warden appointment letter and ID badge verified | HSE Manager | Annually |
| 80 | Fire Safety & Emergency Preparedness (Additional) | Fire hose reel (if installed) tested for pressure and accessibility | Fire hose reel test certificate current | HSE Officer | Quarterly |
| 81 | Waste & Environmental Management | Segregated waste bins (paper, plastic, general) provided and clearly labelled | Waste segregation audit checklist completed | HSE Officer | Monthly |
| 82 | Waste & Environmental Management | E-waste (printer cartridges, batteries) disposed via authorized recycler | Disposal receipt/manifest from licensed recycler on file | HSE Officer | Quarterly |
| 83 | Waste & Environmental Management | Spill kit available near any chemical storage (toner, cleaning agents) in office | Spill kit inventory checklist verified complete | HSE Officer | Monthly |
| 84 | Waste & Environmental Management | Printer/photocopier ventilation adequate to avoid ozone/toner fume buildup | Ventilation check confirmed during air quality inspection | Facilities Supervisor | Quarterly |
| 85 | Vehicle Parking & External Perimeter | Designated parking area for staff/visitor vehicles marked away from office walkways | Parking layout plan verified against site markings | HSE Officer | Quarterly |
| 86 | Vehicle Parking & External Perimeter | Wheel stops/bollards installed to prevent vehicle encroachment onto office walkway | Visual inspection confirms bollards in place and undamaged | HSE Officer | Monthly |
| 87 | Vehicle Parking & External Perimeter | Perimeter fencing/barrier around office compound intact and secure | Fence inspection checklist completed, defects logged | Security Supervisor | Monthly |
| 88 | Vehicle Parking & External Perimeter | External drainage around office maintained to prevent water pooling/flooding | Drainage inspection log after rainfall events | Facilities Supervisor | As required |
| 89 | Vehicle Parking & External Perimeter | Office generator (if used) located in ventilated, bunded area away from office entrance | Generator location and bunding inspection record | HSE Officer | Monthly |
Each checkpoint records Status (Yes / No / N/A), Comments, Corrective Action and Sign-off. Switch to Complete in-app to fill it here, or download the blank version to complete on site.
Next step
Turn this into evidence you can hand over
Replace scattered spreadsheets and WhatsApp threads with one HSE operations system built around UAE authority expectations.
- Built around UAE authoritiesADOSH-SF, Trakhees, DM, DCD, MOIAT and ISO 45001 structures.
- Usable the same dayTemplates and registers are pre-filled with your company details.
- Evidence, not just formsEvery record carries dates, signatures and an export you can hand over.